Lead is the one number in a KK60 part number that trades speed against thrust against resolution. Here is the arithmetic, using the same 1 mm/rev baseline, so you can pick before you quote.
For a ball screw, thrust and speed move inversely with lead at a fixed motor torque and fixed motor speed:
| Lead | Speed at 3000 rpm | Thrust vs 5 mm lead | Resolution per full step (1.8° motor, direct) | Pick it when |
|---|---|---|---|---|
| 5 mm | 15 m/min | 1× (baseline) | 25 µm | Pressing, clamping, dispensing — force matters more than cycle time |
| 10 mm | 30 m/min | 0.5× | 50 µm | General pick-and-place; the default compromise |
| 20 mm | 60 m/min | 0.25× | 100 µm | Long transfer moves where the load is light and the stroke is long |
The numbers above are the direct consequence of lead, not a manufacturer's claim: doubling the lead doubles the distance per revolution and halves the force per unit of motor torque. The step-resolution column assumes a 1.8° stepper with no microstepping and no gearbox; add a 5:1 planetary and divide by five.
Two limits show up before the thrust limit does. The first is critical speed: a longer screw whipping at high rpm. The second is resonance at the stroke ends, which appears as a positioning error that only shows up in one direction. On a 1310 mm stroke, a 20 mm lead is usually chosen for the transfer moves and then run at half the calculated top speed to stay clear of both. If your cycle needs the full 60 m/min at that stroke, you want a larger frame (KK86), not a longer KK60.
15 m/min at 3000 rpm is fine for a press, painful for a gantry. Before you specify 5 mm for thrust, check whether the force you need is actually continuous or only at the moment of contact: a 10 mm lead with a 2:1 belt reduction gives you the same thrust, better resolution and a shorter cycle, at the cost of one more part in the BOM.
Rail width, combined height, hole pitch and motor flange stay the same across leads within a frame size. That is why a lead change is usually the cheapest redesign: the machine's mounting plate does not move. It is also why a "cheaper equivalent" with the same lead can still not fit — the flange is the field that breaks.